Online Chat

JVECRG Eccentric Circles Red Green 1 Pair Clear

Central anti-suppression check. The word FUSE is only seen by one eye, the word TEXT is seen by the other eye, and the word THIS is seen by both eyes.

500.00
SKU: JVBS510-1-1-1-1-1-3-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-32-1-1-1-1-1-1-1-1-1

Description

  • Central anti-suppression check. The word FUSE is only seen by one eye, the word TEXT is seen by the other eye, and the word THIS is seen by both eyes.
  • Fixation disparity check. Small hash mark on the left of the outer ring on one card, and on the right of the ring on the opposite card to help improve accurate alignment and help reduce fixation disparity.
  • Convergence and divergence training when red/green glasses are used. Ex. If the green card is on the right and the green filter is over the left, divergence is done when fusing the two images.
TopicDiscription
PurposeA central anti‑suppression / fusion check and fixation disparity / alignment / vergence training tool under red/green dichoptic conditions.
The “Red/Green” version is specially used in conjunction with red/green filters to enforce monocular separation and force vergence training.
Target usersOptometrists, orthoptists, vision therapists, and their patients. It is not a screening chart for general public but a tool for binocular vision / therapy work.
Optotypes / SymbolsConcentric circles (eccentric circles) printed on each card
Central text: “FUSE” seen by one eye, “TEXT” seen by the other eye, and “THIS” seen by both eyes (in fused view)
Hash / alignment marks: a small hash mark on left side of outer ring on one card, and on right on the matching card
-These features allow anti‑suppression testing and fine alignment judgments.
Scaling / SpacingThe circles are fixed in size (not graded in multiple sizes)
The cards are clear and can be shifted horizontally relative to each other to introduce disparity (i.e. varying spacing)
In a red/green setup, the disparity is controlled by card offset rather than graduated sizes
There is no published graduated scale (in mm or prism) for the offsets in the listing I saw.
Range of Acuity / Line SizesNot applicable (or low relevance) because this is not a visual acuity chart with multiple lines. Its function is binocular fusion / suppression, not measuring high/low acuity levels.
The circles are of fixed size as printed, not graded in many line sizes.
Testing DistanceNear / free‑space (cards held in front of patient)
Meant for near fusion training using red/green filters; not designed for far chart distance.
DimensionsOne general variant: the “Eccentric Circles” product is described as two 6″ × 7″ clear acetate cards.
MountingFree‑space, handheld / clinician‑held — cards are not wall mounted or framed.
The product is designed for binocular free‑space fusion, not mounted charts.
FeaturesAnti‑suppression central check via differential words (“FUSE” / “TEXT” / “THIS”)
Fixation disparity alignment: with hash marks to detect fine misalignments
Vergence training (convergence / divergence) when used with red/green glasses. For example: if green card is on right and green filter is over the left, divergence occurs while fusing.
AccessoriesThe listing shows just the pair of clear red/green eccentric circle cards (i.e. one pair). No extra accessories (frames, stands, filters) are explicitly included in that listing.
Durability / Material QualitiesMaterial: clear plastic / clear acrylic (clear plastic “clear” version as opposed to opaque)
Because the listing emphasizes “clear plastic” version, the cards are likely made from durable plastic sheet rather than paper.
Durability is moderate: plastic offers good resistance to bending and moisture compared to paper, but repeated use may cause scratching, edge wear, or loss of print clarity over time.
Usability / Marker of QualityStraightforward to use in a binocular therapy session (with red/green filters)
The incorporated anti‑suppression text, hash marks, and compatibility with convergence/divergence tasks are markers of a well‑designed, clinically useful tool
Because Good‑Lite is a known brand in vision‑testing/therapy equipment, that gives credibility
The dual‑word / partial overlap design (words visible to different eyes) adds sophistication beyond a simple circle pair
Limitations: absence of published offset scale or calibration, and lack of protective casing may reduce long‐term precision
The presence of features like differential words for suppression check and hash marks for precise alignment distinguishes it from simpler circle pairs, indicating a higher “quality / clinical grade” design.

Reviews

There are no reviews yet.

Be the first to review “JVECRG Eccentric Circles Red Green 1 Pair Clear”

Your email address will not be published. Required fields are marked *